Switch reactors with confidence and certainty
Switching high voltage reactors can impose a severe duty on the connected system, switching device, and shunt reactor. Modern switching devices interrupt the small inductive current shortly after the separation of the contacts. If the interrupter’s contacts have not separated enough to sustain the rapidly rising TRV , a re-ignition of the arc will occur. These high magnitude and high frequency re-ignitions can shorten the life of the reactor and the switching device. The Southern States’ RLSwitcher®, with its’ patented interrupter design, has helped satisfied customers minimize the probability and magnitude of these harmful re-ignitions since 2010.
Tertiary Reactor Switcher
Southern States’ success has recently led to the development of our new RLS38T, an RLSwitcher® designed specifically for transformer Tertiary connected shunt reactors rated 15.5kV and 38kV. The RLS38T’s unique contact set helps address the need for high switching current (up to 3000A) required at lower voltages. By minimizing re-ignitions and maintaining contact life, it provides increased life and reliability for utilities. For more information, please take a moment to visit our published news release.
- Interrupter design making and breaking an SF6 minimizes probability and magnitude of re-ignitions, thus providing the following benefits:
- Reduced Turn-to-Turn voltage stress on reactor windings
- Minimized damage to the switching device nozzle and contacts, thus providing long life
- Minimized harmful transients on the systems
- Simplified design improves reliability
- Gas system monitoring provided for all devices
- Compact design can fit is tight spaces
- Single mechanism spring-open, spring-close mechanism provides reliable long-life performance for less than or equal to 245kV
- Fully assembled and tested at the factory
- Ships with minimum dis-assembly to minimize installation time
Reactor Switching
| Maximum Voltage | Reactor Switching Current | Shunt Reactor Rating |
| 38 kV | 1600 A | 105 Mvar |
| 72.5 kV | 539 A | 67 Mvar |
Additional Ratings
| Maximum Voltage Rating | 38 kV | 72.5 kV |
| Continuous Current Rating | 1600 A | 1200 A |
| Power Frequency | 50/60 Hz | |
| BIL | 200 kV | 350 kV |
| Short Circuit Breaking Current | 25 kA | 40 kA |
| Interrupting Time | 5 cycles | 3 cycles |
| Short-Time Withstand | 25 kA (3 sec) | 40 kA (3 sec) |
| Short-Circuit Making | 25 kA | 40 kA |
| Peak Withstand | 62.5 kA | 104 kA |
| Insulator Design | Porcelain | |
| Ambient Temperature Range | -40º C to +50º C | -30º C to +50º C |
Catalog Flyers & Bulletins
RL Switcher 38kV-72.5kV Catalog Flyer
RLSwitcher 123kV-550kV Catalog Flyer
RLSwitcher® Tertiary Reactor Switching Device 15.5kV-38kV
General Information
Presentation RLSwitcher for Tertiary Reactors
Standard & Optional Features-15.5kV and 38kV Tertiary Reactor Switcher
RLS38T News Release
Standard Features & Optional Features for the 72.5kV through 170kV RLSwitcher’s Spring Operating Mechanism
Specification Guides & Drawings
245kV RLSwitcher Product Specification Guide(Download Word Document)
362kV RLSwitcher Product Specification Guide(Download Word Document)
550kV RLSwitcher Product Specification Guide(Download Word Document)
72kV RLSwitcher Product Specification Guide(Download Word Document)
Outline Drawing Tertiary Shunt Reactor Switching
RLSwitcher® Tertiary Reactor Switcher Specification Guide(Download Word Document)